Convenient Functions | -Long Memory Max. 32KBytes/CH for flexible Waveform Zoom In/Out -Direct Single Trigger Capture Function using a hot-key -Simultaneous 5 Waveform informations -Auto Measurement and FFT Analysis -Auto Trigger Level Setting to 50% -Saving 10 Waveforms & setup parameters -Convenient inserting interface card for RS-232C, Hardcopy and USB |
ACQUISITION | Max. sample rate | 200MSPS for one channel only, 100MSPS/CH (real time), 25GSPS/CH (equivalent) | Record length | Long Memory Max. 32kBytes/CH, Wide Waveform Zoom In/Out | Peak defect | Capture & displays event as narrow as 10ns GLITCH | |
VERRICAL | Frequency bandwidth | DC-250MHz | Input channel | CH1, CH2 | VOLTS / DIV | 2mV.DIV~5V/DIV | Input impedence | 1 Mohm // Approx. 20pF | Max. input volt | 300V (DC+AC Peak) (AC < 1kHz) | Accuracy | 3% | Input coupling | DC, AC, GND | Rising time | Approx. 2.3ns | |
MATH | -Arithmetric(ADD, SUBSTRACT, INVERSION) -FFT : Hamming, Hanning and Retangular window |
HORIZONTAL | TIME / DIV | Equivalent 2ns/div ~ 0.1μs Realtime 0.25 μs/div~0.1s/div Roll mode 0.2s/div~5s/div | Resolution | 80ps | Accuracy | 0.01% | Pre trigger | Max. 10div | magnification | ZOOM IN/OUT | |
TRIGGER | Mode | AUTO, NORMAL, SINGLE | Coupling | DC, AC, LF REJECT, HF TRJECT | Type | EDGE, TV | SLOPE | + or - | Level | Manual setting or Automatic 50% setting | Source | CH1, CH2, EXT, LINE | Sensitivity | TRIGGER | FREQUENCY | SENSITIVITY | 5mV~5V/div | 2mV/DIV | INTERNAL (CH1, CH2) | DC~20MHz | 0.5 DIV | 0.5 DIV | 20MHz~80MHZ | 1.5 DIV | | 80MHz~150MHz | 2.0 DIV | EXTERNAL | DC ~ 10MHz | 0.2 Vp-p | | |
DISPLAY | 5.7" MONO LCD (320 X 240) |
MENU | Display | Type Dots, Vectors Format X-Y, Y-T GRID Full, Cross, Board Contrast Control possible | SAVE / RECALL | 10 Setup, 10 Waveforms This function is able to save waveform and setting state of present working environment and recall by the user. Factory setup recall | UTILITY | Self Calibration System condition | Cursor | Type : time, frequency, Voltage Source : CH1, CH2 | Measure | Max. 5 parameter auto measurement (pk-pk, RMS, Mean, Frequency, Rising time, Falling time, period, Positive width, Negative width, Duty) | |
HOT-KEY | AUTO SET | VARTICAL, HORISONAL & Trigger setting | RUN/STOP | Waveform hole | SINGLE | Bandwidth 10MHz | HARDCOPY | Hardcopy through printer port or RS-232 port for thermal printer | |
POWER | Power supply | 90V AC ~ 250V AC | Frequency | 48Hz ~ 440Hz | Power consumption | 30W | |
WEIGHT | -6kg |
SIZE | -338(W) x 167(H) x 371(L) |
EMC | -CE (EN55011, EN50082-1) |
SAFETY | -CE (EN61010-1), meet UL3111-1 |