APPA 99II Digital Multimeters


By APPA
SKU : 0
DC voltage 400 mV - 1000; AC voltage of 400 mV - 750 V; DC / AC current of 40 mA - 10 A; The resistance of 400 ohms - 40 MW; 4 Hz - 40 MHz; Capacity 4 nF - 40 mF; Temperature Measurement; Withholding evidence; Linear scale; Lighting; Test pn; Rang chain; Rotation frequency; Measurement of the rms value of arbitrary waveform True RMS; Relative measurements
AED 425.00



Description

Digital Multimeters APPA 99II (APPA Technology Corporation): Brief specifications: DC voltage 400 mV - 1000; AC voltage of 400 mV - 750 V; DC / AC current of 40 mA - 10 A; The resistance of 400 ohms - 40 MW; 4 Hz - 40 MHz; Capacity 4 nF - 40 mF; Temperature Measurement; Withholding evidence; Linear scale; Lighting; Test pn; Rang chain; Rotation frequency; Measurement of the rms value of arbitrary waveform True RMS; Relative measurements.

High-contrast LCD display, which is equipped with models in this series, will allow you to easily read the testimony of the display in bright sunlight, and, thanks to built-in lighting, in absolute darkness. To increase the life of batteries, the display backlight has the function of Auto. Completely new design repeating the outlines of the letters V, red body and gray protective cover are new millennium test and measurement equipment. Each device series APPA 90II is equipped with a protective casing which has a stand, hanging hole, and lock the probe. This housing provides a high degree of safety and ease of use of your device. Now, for the replacement of the batteries is not necessary to disassemble the housing. The battery compartment is located under a small cover held by only one screw. Ergonomic design with comfortable touch probe fins, with thrust ring prevents fingers from slipping, with a molded wire reliably and the tip of solid steel for long life. Includes removable clamps type "crocodile". For models with temperature measurement adapter supplied in the kit and the sensor for measuring the temperature.

 

 

 

 

Detailed specifications Multimeter APPA 99 ii

 

Option Values
Constant voltage
Measurement range 400 mV; 4; 40; 400; 1000
Accuracy ± (0,25% + 1 unit. Account)
Maximum resolution 0.1 mV
Input impedance 10 megohms
Input Protection 1000
AC voltage
Measurement range 400 mV; 4; 40; 400; 750
Accuracy ± (1,3% + 5 units. Account)
Maximum resolution 0.1 mV
Bandwidth 40 Hz ... 1 kHz
Input impedance 10 MW / 100 pF
Input Protection 1000
DC
Measurement range 40; 400 mA; 10A
Accuracy ± (0,6% + 2 units. Bills)
Maximum resolution 10 uA
Input Protection Fuse 16 A / 500 V (input "A"); 1 A / 500V (input "mA")
Alternating current
Measurement range 40; 400 mA; 10A
Accuracy ± (2,0% + 5 units. Bills)
Maximum resolution 10 uA
Bandwidth 40 Hz ... 1 kHz
Input Protection Fuse 16 A / 500 V (input "A"); 1 A / 500V (input "mA")
Resistance
Measurement range 400 Ohm; 4; 40; 400 ohms; 4; 40 megohms
Accuracy ± (0,7% + 3 units. Bills)
Maximum resolution 0.1 Ohm
Test voltage 1.5
Input Protection 600
Rang chain
Threshold 30 ohms
Indications continuous sound frequency of 2 kHz
Input Protection 600
Test PN
Maximum current test 1.5 mA
Voltage test 3
Input Protection 600
Frequency
Measurement range 4; 40; 400 kHz; 4; 40 MHz
Accuracy ± (0,01% + 1 unit. Account)
Maximum resolution 1 Hz
Sensitivity 100 mV
Input Protection 600
Rotation frequency
Measurement range 40; Cob 400 / min; 4; 40; Mobile: 400 / min
Accuracy ± (0.01% + 10. Account)
Maximum resolution 30 rev / min
Sensitivity 100 mV
Input Protection 600
Capacity
Measurement range 4; 40; 400 nF; 4; 40; 400 uF; 4; 40 mF
Accuracy ± (2,0% + 8 units. Bills)
Maximum resolution 1 pF
Input Protection 600
Temperature
Measurement range -20 ° C ... 800 ° C; 
-4 ° F ... 1472 ° F
Accuracy ± (1,0% + 3 ° C); 
± (1,0% + 6 ° F)
Maximum resolution 1 ° C; 1 ° F
Input Protection 600
Total information
Measurement Wed. sq. char. Arbitrary Waveform
Maximum number Displayed 4000
Linear scale 82 segment
Measurement speed Digital Scale: 2 rev. / s 
linear scale 12 rev. / s
Auto Power Off 30 minutes (auto power off can be locked)
Power supply 9 (type "Crown")
Battery life 300 h
Terms of Use Temperature: 0 ° C ... 50 ° C; Relative humidity: not more than 80%
Dimensions 94 x 188 x 40 mm
Weight 490 g

 